EICR in Islington, Islington has some of London’s most characterful homes: Georgian terraces in Canonbury, Victorian conversions off Upper Street, and post-war flats around Holloway. Beneath those period features, the electrics are often a patchwork of repairs and upgrades made over several decades. Most of the time it all works, until it doesn’t.
That is why an EICR in Islington matters. An Electrical Installation Condition Report is a formal assessment of your property’s fixed wiring and the safety equipment connected to it. At London Property Inspections, we regularly find faults that were invisible to the owner, the tenant, and sometimes even the previous electrician. Here are seven of the most common, and what to do about each.
What a Periodic Electrical Inspection Actually Checks
Before the faults, it helps to know what the report covers. A qualified inspector tests your installation against BS 7671, the UK Wiring Regulations (currently the 18th Edition, Amendment 2). They examine the consumer unit, circuits, sockets, switches, lighting, earthing and bonding, and they carry out live and dead tests to measure how the system performs.
Any issue is given a code:
- C1: Danger present, immediate action required.
- C2: Potentially dangerous, urgent remedial work needed.
- C3: Improvement recommended.
- FI: Further investigation required without delay.
A report with any C1, C2 or FI code is classed as “unsatisfactory”. Remember that, as it comes up throughout the faults below.
1. Deteriorating Wiring and Insulation
Older Islington properties often still contain cabling from the mid-20th century or earlier, including rubber-insulated or fabric-sheathed cables. Insulation naturally becomes brittle and cracks over time. Once that protective layer breaks down, the risk of short circuits, electric shock and fire rises sharply.
Example: In one Barnsbury flat, the owner had no idea that the lighting circuit still used original rubber-coated cable. It looked fine at the fittings, but testing showed the insulation resistance had dropped well below the safe threshold.
Tip: If your home has round-pin sockets, cloth-covered cable or a fuse box with rewirable fuses, expect your inspector to look at the age of the wiring closely.
2. Overloaded Circuits and Inadequate Protection
Homes built decades ago were never designed for today’s electrical demand. Think induction hobs, electric showers, home offices, EV chargers and a dozen devices on charge in every room. When too much load is placed on a circuit, cables run hot and protective devices may not trip as they should.
An electrical safety report often reveals:
- Several high-demand appliances sharing one circuit.
- Extension leads daisy-chained to cope with a lack of sockets.
- Circuit breakers with the wrong rating for the cable they protect.
Tip: If your lights flicker when the kettle goes on, or a breaker trips regularly, don’t just reset it. That is a symptom worth investigating.
3. Missing or Ineffective RCD Protection
Residual Current Devices (RCDs) cut the power in milliseconds if they detect a dangerous leakage of current, for example when someone touches a live part. Modern regulations expect RCD protection on most circuits, yet many older installations have none, or have devices that no longer work.
This is one of the most frequent C2 observations we record. An RCD that has seized after years of never being tested may look fine on the panel but fail when you need it. Every RCD has a test button, and it is worth pressing it every few months.
Tip: If your consumer unit has no RCDs at all, upgrading is among the most valuable safety improvements you can make.
4. Poor Earthing and Bonding
Earthing gives fault current a safe path to the ground, and bonding keeps metalwork such as gas and water pipes at the same electrical potential. When either is missing or inadequate, a simple appliance fault could make a radiator, tap or metal casing live.
In older buildings, we often find:
- Bonding clamps that have corroded or been removed during plumbing work.
- Bonding conductors that are too small.
- Plastic pipework fitted by a plumber, which has quietly interrupted the earth continuity.
Poor earthing is also hard to spot visually, which is why the testing side of an inspection matters so much.
5. An Outdated or Non-Compliant Consumer Unit
The consumer unit (fuse box) is the heart of your electrics. Many Islington homes still have older ceramic fuse boards, or early plastic units that don’t meet current standards. Modern regulations favour metal enclosures because they contain fire far better.
Inspectors also look for:
- Missing blanking plates leaving live parts exposed.
- Poorly labelled circuits.
- Overcrowded units with makeshift additions.
- Signs of heat damage or scorching.
Example: A landlord of a Highbury maisonette assumed the plastic consumer unit installed years earlier was fine. The report noted it as an improvement point, and the landlord replaced it during a refurbishment. It was a sensible, cost-effective decision.
6. Loose Connections and Hidden Overheating
Loose terminations are a leading cause of electrical fires, and they are rarely visible. A connection that isn’t tight enough creates resistance, which creates heat. Over months or years, that heat can damage insulation and surrounding materials.
During a periodic inspection, signs of this problem include discoloured sockets, a burning smell, crackling sounds, or warm faceplates. Thermal imaging can help pinpoint overheating that is hidden behind plaster or inside the consumer unit.
Tip: If a socket or switch feels warm, discolours or buzzes, stop using it and call a qualified electrician.
7. Unsafe DIY Alterations and Bad Past Repairs
Over the years, previous owners, landlords and “a friend who knows a bit about electrics” may have altered the circuits. We often uncover:
- Junction boxes buried under floorboards or plaster, with no access for inspection.
- Spurs added without proper protection.
- Incorrect cable types or sizes.
- Light fittings wired without an earth.
- Work carried out near bathrooms without proper zoning.
These faults are especially common after refurbishments in converted houses, where wiring has been extended piecemeal to serve new layouts. Good work should always be documented and tested; poor work rarely is.
Booking an EICR in Islington: Legal Duties and Timing
If you are a landlord in England, the law is clear. Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, private landlords must have the electrical installation inspected and tested at least every five years by a qualified person. You must give a copy of the report to existing tenants within 28 days and to new tenants before they move in. If the report is unsatisfactory, remedial work must be completed within 28 days, or sooner if the report specifies.
Electrical faults rarely announce themselves. They sit quietly behind walls, under floors and inside consumer units until a surge, a damaged cable or a sleepy RCD turns them into something far more serious. A thorough EICR in Islington brings those hidden problems into the light, giving you a clear, coded list of what’s safe, what’s urgent and what can wait.
FAQs
1. How long does an electrical inspection take?
For a typical flat, expect between two and four hours. Larger houses with more circuits can take longer. The power will need to be switched off briefly at various points, so it helps to plan ahead.
2. What happens if my report is rated “unsatisfactory”?
It means there are C1, C2 or FI observations. Remedial work should be carried out promptly. Landlords in England must complete it within 28 days (or any shorter period stated in the report) and send written confirmation to tenants and, where requested, the local authority.
3. Can I do the inspection myself?
No. Inspection and testing require specialist equipment and training. Only a competent, qualified electrician should issue a formal report.
4. How often should I renew my report?
Landlords in England must do so at least every five years. For owner-occupied homes, every ten years is the usual guidance, or sooner if you notice problems or make major changes.
5. Do new-build properties need one?
New installations come with certification at handover, so a periodic report isn’t usually needed straight away. After that, the same renewal intervals apply.